Installation

1. Install the EPC solenoid.

1

Install the EPC solenoid.

2

Install the EPC solenoid bracket and bolt. 
^

Tighten to 10 Nm (89 lb-in).

2. Inspect the molded lead frame for damage.

^

Using the special tool, check all molded lead frame solenoid connections. The gauge should fit tightly and not fall out after being inserted.

^

If the special tool passes through any molded lead frame connector pins or does not feel like it makes a good contact, install a new molded lead
frame.

3. Connect the molded lead frame to the solenoids.

^

Connect the bulkhead interconnector by pressing it in place by hand and fully seating the connector in place.

^

Connect the EPC solenoid by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals pass fully
through the connector slots.

^

Connect the TCC by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals pass fully through the
connector slots.

^

Connect the shift solenoid SSA and SSB by pressing it in place by hand and fully seating the connector in place. Make sure that the terminals
pass fully through the connector slots.