lincoln Workshop Repair Guides

Lincoln Workshop Service and Repair Manuals

Accumulator HVAC|Service and Repair|Page 6929 > < Wheel Fastener|Front|Page 6924
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. With the vehicle in NEUTRAL, position it on a hoist.
2. Recover the refrigerant.
3. Disconnect the suction accumulator outlet fitting.

-

Discard the O-ring seals.

4. Disconnect the suction accumulator inlet fitting.

-

Discard the O-ring seals.

5. Disconnect the A/C cycling switch electrical connector.
6. Remove the 3 suction accumulator bolts.

-

To install, tighten to 15 Nm (11 lb-ft).

7. Remove the suction accumulator.
8. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.