8. Remove the condenser inlet fitting nut and disconnect the fitting.

-

Discard the gasket seal.

-

To install, tighten to 15 Nm (11 lb-ft).

9. Remove the compressor manifold and tube assembly.

10. To install, reverse the removal procedure.

-

Install new gasket seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

11. Evacuate, leak test and charge the refrigerant system.