4. Disconnect red 10-pin plug connection.
5. Pull plug connection off reserve power source.
6. Unscrew the 2 lower sheet metal clips for fastening the plate.
7. Unscrew fastening bolt and remove reserve power source.
Installing:
8. Slide holder in cutout of plate and fasten reserve power source with sheet metal bolt from the rear.
9. Connect plug connector to reserve power source.
10. Test system with tester. See "Test Program, Tests, Test Instructions for Tester..." See: Testing and Inspection/Component Tests and General
Diagnostics
11. Continue installation in the reverse sequence.
12. Check system with RS/SRS warning lamp.