Battery: Testing and Inspection
Battery Condition

Turbo

1.

Check battery housing for cracks or leaks.  If any are found replace the battery.

2.

Check battery terminals for tight connection and white crystal deposits.  If terminal condition is suspect, clean battery terminals and retighten.

3.

Check electrolyte level.  If low, fill battery with distilled water to minimum level mark and charge the battery at a safe rate.

CAUTION:  When working with batteries, always wear eye protection and never lean over batteries.  During recharging and when performing the
capacity test, remove the battery caps.  
    Temperature of electrolyte in any cell must not exceed 51°C (125°F) at anytime during charging to prevent damage to battery or explosive condition
from occuring.  Reduce charging rate if battery starts forming gas.

4.

Perform hydrometer test.  All cells must read above 1.240.  If this reading is not obtained, recharge battery until specific gravity is above 1.240 for
all cells.

5.

Perform battery capacity test.  Apply a load of triple the battery capacity for 10 seconds.  Voltage must not drop below 10 Volts for a specific
gravity of 1.280, or 9 Volts for a specific gravity of 1.240.  If the battery meets these specifications, it is good.  If not, replace the battery.

Non Turbo

1.

Check battery housing for cracks or leaks.  If any are found replace the battery.

2.

Check battery terminals for tight connection and white crystal deposits.  If terminal condition is suspect, clean battery terminals and retighten.

3.

Check electrolyte level.  If low, fill battery with distilled water to minimum level mark and charge the battery at a safe rate.

CAUTION:  When working with batteries, always wear eye protection and never lean over batteries.  During recharging and when performing the
capacity test, remove the battery caps.  
    Temperature of electrolyte in any cell must not exceed 51°C (125°F) at anytime during charging to prevent damage to battery or explosive condition
from occuring.  Reduce charging rate if battery starts forming gas.

4.

Perform hydrometer test.  All cells must read above 1.240.  If this reading is not obtained, recharge battery until specific gravity is above 1.240 for
all cells.

5.

Perform battery capacity test.  Apply a load of triple the battery capacity for 10 seconds.  Voltage must not drop below 10 Volts for a specific
gravity of 1.280, or 9 Volts for a specific gravity of 1.240.  If the battery meets these specifications, it is good.  If not, replace the battery.