Cold Start Injector: Testing and Inspection
Testing Start Valve Actuation
Testing start valve actuation
Preceding work:
Testing starting device. See: Testing Start Device
-
Connect testers:
-
multimeter (003)
-
ohms decade (038)124 589 09 63 00.
-
Test starting voltage. At least 10 V in approx. 5 seconds.
-
Test electric wiring between starting valve and fuel pump relay for continuity. Resistance approx. 0 ohm.
-
a) Vehicles with actuation via thermo-time switch (S26)
-
Test thermo-time switch (S26) (102.961 USA).
-
b) Vehicles with actuation via fuel pump relay module
-
Test voltage at fuel pump relay module. Contact 12 (terminal 50) at least 10 V, contact 2 (terminal TF).
Special Tools
Commercially Available Tester