2.
Position plate (arrow) on removable magnetic block (02, Figure 3).
3.
Place bridge (arrow, Figure 4) on both rollers of connecting link so that the heads of the connecting link pins sit in the slot (c) ensuring proper
positioning of the pins into the bores of the plate.
4.
Tighten spindle (04, Figure 4) with a box wrench until firm resistance is felt.
5.
Remove assembly tool 000 589 58 43 00 position removeable block
(02, Figure 5) so that groove (D) faces inward (see Figure 5).
6.
Position assembly tool and individually rivet both pins by tightening spindle to 30 Nm.