mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 7385 > < Diagram Information and Instructions|Page 7383
Page 2
background image

This consists of a temperature selector wheel (a). pushbutton switch (b) with five pushbuttons and the blower switch (c).

The control unit houses electronics with the following functions:

1. Control of the interior temperature and activation of the refrigerant compressor with ground via the control unit compressor shut-off.

2 Control of the blower control unit.

3. Control of the circulated air operation.

4. Control of the air flaps.

The respective outputs of the control unit are designed short-circuit proof. This feature protects the conductor boards in the control unit during a
short-circuit.

The function of the short-circuit safety feature is designed differently by the respective manufacturers of the control unit.

Diagram Information and Instructions|Page 7385 > < Diagram Information and Instructions|Page 7383