mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Canister Purge Control Valve|Locations > < Emissions - Catalytic Converter EPA Replacement Warning|Page 4438
Page 1
background image

Canister Purge Control Valve: Specifications

Breather Valve Opening Pressure.............................................................................................................................................30-50 mbar (0.435-0.725 psi.)
Breather Valve Opening Vacuum.........................................................................................................................................1-16 mbar (0.0295-4.728 in. Hg)
Oxygen Sensor Operating Temperature........................................................................................................................................350 - 850°C (660 - 1560°F)
Purge Valve Opening Vacuum..............................................................................................................................................20-35 mbar (0.591-1.034 in. Hg)
50°C Thermovalve Open.........................................................................................................................................................................Above 50°C (122°F)