300E (124.030) L6-3.0L (103.983) (1986)
5.
Attach clamp (2, Figure 5) for the drainage pipe (1) to the coolant pump housing.
NOTE!
The retaining loop of the clamp must point toward the timing cover.
6.
Remove/install lower encapsulation panel (SMS, Repair Instructions, Job no. 01-006).
7.
Attach drainage pipe clamps (2, Figure 6) to the generator bracket with the lower attachment bolt (3) and with a M8 x 10 hex bolt (4) at the
cylinder crankcase.
NOTE!
Align the drainage pipe. It must be routed vertically downward.
After installation, make sure there is sufficient clearance between the drainage pipe and all moving parts.
Parts Information
Part Name
Part Number
Drainage pipe kit
102 200 OB 52
In Case of Warranty
Operation: Coolant pump drainage pipe, retrofit (02-2028)