6
Connect pressure lines (B2 and B3), making sure that line (B3) designed as pressure hose is not chafing against frame floor.
7
Fill pressure oil system and check for leaks. See: Service and Repair
Attention!
When scrapping pressure reservoirs, respective safety rules must be observed.
Carefully release pressure reservoirs with gas filling screw (1st to 3rd version) on dome-shaped face, let gas flow out end completely remove
screw (arrow).