300SL (129.061) L6-3.0L (104.981) (1991)
7.
Install male connector housing (1, Figure 2) to cut off branch (a, Figure 1) of old transmission wiring harness, and connect wires as shown in the
table.
Model
140.042/051/057
140.032
Location 1
BK
BK/GN-RD
Location 2
----
Location 3
BK/RD
BK/RD
Location 4
----
8.
On the new transmission wiring harness (2), cut away branch (a) approximately 200 mm (8 inches) from its entry point into the harness and
discard. Solder connector sockets (part number 003 545 06 26) to wire ends of the transmission wiring harness (2). (Figure 3)