Air Door Actuator / Motor: Service and Repair
Main Air Flap

Removal

1. Remove glove box.
2. Remove right cover under instrument panel.

Main Air Flap Vacuum Element And ETR Switch

3. Pull vacuum line from vacuum element (42).
4. Force linkage from lever for main air flap with a screwdriver and disconnect linkage.
5. Remove locks on vacuum element (42) with a screwdriver and remove vacuum element from holder.

Installation

1. Clip vacuum element (42) to holder, using new locks with rubber washers underneath.
2. Push linkage on lever for main air flap.
3. connect vacuum line on vacuum element (42).
4. Install right cover under instrument panel.
5. Install glove box.