300TD (123.193) L5-3.0L DSL Turbo (617.952) (1984)
Pressure Switch With O-Ring Seal
2nd Version
2. Mount temperature switch (14) and pressure switch (13) on receiver drier (17). On pressure switch 1st version (cone seal), moisten threads and
cone with cold-flowing oil. Pressure switch (2nd version) with 0-ring (13) check and renew, if required.
3. Mount electric plug on temperature switch (14) and pressure switch (13).
4. Evacuate a/c system and refill. SEE Heating and Air Conditioning. See: Service and Repair
5. Check a/c system for function. SEE Manual (Visual) Function Tests See: Testing and Inspection/Component Tests and General
Diagnostics/Automatic Air Conditioning (Auto A/C)/Manual and Visual Function Test of Automatic Climate Control