mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Evaporator Core|Specifications > < A/C - Modified Evap. Switch & In Car Temp Sensor Info.|Page 4904
Page 7
background image

FIGURE 11

Exchanging  Air Flaps

1.

Remove instrument panel, (Job 68 - 100)

2.

Remove clip (9) on left and right side of airduct (Figure 11).

3.

Pull flap shaft (common shaft for right and left flap) out to the right, but only far enough to allow the flaps to be removed.

CAUTION: Do not drop the shaft end bushings into the housing when removing flaps. If a busing is dropped into the housing it must be removed

to prevent future noise complaints.

4.

Examine the eyelet on the nap removed from the right side for any signs of cracks or damage. If none, exchange left with right air flap and
reinstall shaft and clips.

5.

Check to be sure that the flaps open and close without binding. If a new attachment rivet is needed, use part no. 000 990 34 92.

6.

The remaining re-installation is performed in reverse order.

FIGURE 12

NOTE:

To prevent flap damage during reassembly before installing the instrument cluster, apply vacuum to the element to close the flap as shown in
Figure 12. Keep the flap in this position by locking the linkage of the vacuum element with a wedge (arrow). After the instrument panel is
installed remove the wedge.

Time Allowance

83-S36-01 Major Operation

8.9 hours

83-S36-02 Related Operation

8.7 hours

Evaporator Core|Specifications > < A/C - Modified Evap. Switch & In Car Temp Sensor Info.|Page 4904