REPLACEMENT PROCEDURE:
TIGHTENING TORQUES:
Pressure hose to receiver dehydrator:
with Cu seal:
45±5 Nm (4.5±0.5 kpm)
without Cu seal:
55±5 Nm (5.5±0.5 kpm)
Pipe line to receiver dehydrator:
with Cu seal:
30±5 Nm (3.0±0.5 kpm)
without Cu seal:
45±5 Nm (4.5±0.5 kpm)