mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

A/C - R12 to R134a Conversion|Page 5036 > < A/C - R12 to R134a Conversion|Page 5034
Page 4
background image

Figures 2 and 3

9.

Refill recycled R12 once again into A/C system.

10.

Operate A/C system again, as in above steps 7-13 for approx. 10 minutes.

CAUTION: 

Should the A/C compressor become noisy, stop engine and continue with "D. Replacing Receiver Drier.

11.

Using air conditioning service equipment, evacuate the R12 at high. and low-pressure sides (A, Figure 2 and B, Figure 3) of A/C system for 45
minutes.

Note

A/C service equipment should be able to pull at least 29.2" of vacuum.

CAUTION: 

At this point, R12 is not be used in A/C system again.

D.

Replacing Receiver/Drier
Please see SMS, Repair Instructions, Job No 83-540.

E.

Installation of Service Valves

CAUTION: 

Prior to the installation of the angled service valve (Figure 6) or adapter hose (4, Figure 7) the existing Schrader valve core (arrow, Figure 4) located
in A/C line must be removed.

A/C - R12 to R134a Conversion|Page 5036 > < A/C - R12 to R134a Conversion|Page 5034