21. Connect battery, turn ignition key to position "1" and test system by means of the RS warning lamp.
22. Turn ignition key to position "0". Disconnect battery negative terminal and cover.
23. Disconnect red 10-pin plug connection (arrow).

a Red line 
b Red-green line

24. Connect electrical connections and vacuum lines to blower switch.
25. Route connection cable and fasten with cable straps.

26. Insert air distribution switch (right) to the left and blower switch (left) downwards into the retaining plate.

27. Insert retaining plate at the mounting bolts and align so that the distance between the outer edge of the opening in the center console and the outer

edge on the bores for the control switches is 15 mm.

NOTE:  The cover can be used as an auxiliary dimension line.