mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 5377 > < Procedures|Page 5375
Page 10
background image

29. Insert retaining plate at the mounting bolts and align so that the distance between the outer edge of the opening in the center console and the outer

edge on the bores for tne control switches is 15 mm.

NOTE:  The cover can be used as an auxiliary dimension line.

30. Screw mounting bolts on retaining plate.
31. Test system with tester. See: Testing and Inspection/Component Tests and General Diagnostics
32. Continue installation in the reverse sequence.
33. Check system with RS warning lamp.

34. Tie string to red 10-pin plug of control unit and route connecting cable through the front wall pillar with the aid of this string.
35. Check system using tester, see "Test Instructions for Tester...", which is contained within the article at "Test Program, Air Bag and Belt Tensioner

(up to 09/87) and Air Bag 1/3, Tests". See: Testing and Inspection/Component Tests and General Diagnostics 

NOTE:  On vehicles up to 9/87, test steps 2, 6 and 7 found under "Test Instructions for Tester..." are no longer required with the installation of air bag
1/3.

36. Continue installation in the reverse sequence.
37. Check system with the aid of the RS warning lamp.

-

Connect test coupling/plug connection, airbag, 10-pin (X29/9).

-

Switch on ignition. The RS or SRS warning lamp must go out after approx. 4 s.

Supplementary Work When Installing Modified Control Unit (1/3)

Procedures|Page 5377 > < Procedures|Page 5375