7. Remove belt tensioner from center pillar and pull off plug connection.

WARNING:  Do not hold belt tensioner unit at turbine wheel. If the propellant is accidentally ignited the turbine wheel is rapidly accelerated
(risk of injury).

Installing:

Installation Note:  When installing the belt tensioner(s), note that there are different versions (for left and right) and ensure that it locates correctly in
locking device.

  

8. Connect belt tensioner by means of the plug connection (plug connection mus engage audibly).
9. Install belt tensioner. Tightening torque of mounting screw is 35 Nm.

10. Test system with tester.
11. Continue installation in reverse sequence.
12. Check system with RS warning lamp.