C 230 (203.040) L4-1.8L SC (271.948) (2005)
1
Disconnect ground cable of battery
2
Unscrew screws (1)
NOTE: Three screws.
-
See "Special Tools" given below.
4
Remove left and right defroster flaps actuator motor (M2/16)
NOTE: from heater/AC housing.
5
Disconnect connector (3) from left and right defroster flaps actuator motor (M2/16)
6
Install in the reverse order.
7
Synchronize left and right defroster flaps actuator motor (M2/16).
Special Tools
Torx bit set, P/N# 000 559 01 10 00
AR83.10-P-2010P Remove/Install Actuator For Left Vent Flap
AR83.10-P-2010P Remove/Install Actuator For Left Vent Flap
- with CODE (581) Comfort automatic air conditioning
Shown on Model 203.0
DANGER:
-
Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte Injury hazard and danger
of burning skin and eyes when handling battery acid or handling damaged lead-acid batteries