mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Air Duct > < AR83.10-P-2001P Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 13228
Page 17
background image

DANGER:

-

Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte Injury hazard and danger
of burning skin and eyes when handling battery acid or handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid protection gloves, clothes and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2

Remove AC housing

3

Unscrew screws (1)

NOTE:  Two screws.

-

See "Special Tools" given below.

4

Remove activated charcoal filter flap actuator motor (A32m2) from AC housing (2)

5

Disconnect connector (3) from activated charcoal filter flap actuator motor (A32m2)

6

Install in the reverse order

7

Synchronize activated charcoal filter flap actuator motor (A32m2).

Special Tools

Torx bit set, P/N# 000 559 01 10 00