C 320 CL (203.764) V6-3.2L (112.946) (2004)
Shown on Model 203.0
DANGER:
-
Risk of explosion from electrolytic gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Injury hazard and
danger of burning skin and eyes when handling battery acid or handling damaged lead-acid batteries
-
No fire, sparks, naked flames or smoking.
-
Wear acid protection gloves, clothes and goggles. Pour battery electrolyte only into suitable and appropriately marked containers.
1
Disconnect ground cable of battery
2
Remove instrument panel
3
Expose lead
NOTE: Cockpit wiring harness in area of right defroster flap actuator motor (M2/9).
4
Unscrew screws (1)
NOTE: Three screws.
-
See "Special Tools" given below.
5
Remove right defroster flap actuator motor (M2/9) from AC housing
6
Disconnect connector (3) from right defroster flap actuator motor (M2/9)
7
Install in the reverse order
8
Synchronize right defroster flap actuator motor (M2/9)
Special Tools
Torx bit set, P/N# 000 559 01 10 00
AR83.10-P-2006P Remove/Install Actuator For Left Footwell Flap