C 320 CL (203.764) V6-3.2L (112.946) (2004)
7
Expose wiring harness.
8
Remove front SAM control module with fuse and relay module (N10/1) upwards.
NOTE: Pull out only until connectors are accessible from below.
9
Release and remove connectors
NOTE:
-
At top on front SAM control module with fuse and relay module (N10/1)
-
Removal: Disconnect cables from control module and fuse and relay box
-
Installation: Connect cables on control module and fuse and relay box
10
Remove front SAM control module with fuse and relay module (N10/1).
NOTE: When replacing, the fuse and relay assignment must be inspected.
11
Install in the reverse order
12
Perform basic programming
13
Read diagnostic trouble code memory and erase
14
Check for proper function