mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 2296 > < Procedures|Page 2294
Page 3
background image

Component Identification

Application of sealant to end cover 

The lines drawn G, E and the arrow D mark the application of sealant.

Clean sealing surfaces, apply sealant only to the specified surfaces with a bead of 2.0 mm ± 0.5 mm.

The sealant must be applied within 10 minutes!

The silicone bead must not be spread. Only the approved silicone sealant may be used may be used.

AR01.40-P-8913AC Remove/Install End Cover

AR01.40-P-8913AC Remove/install end cover

Component Identification

Procedures|Page 2296 > < Procedures|Page 2294