mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Instruments - Erratic Illumination/Control Functions|Page 446 > < A/C - No Or Insufficient Cooling Output|Page 436
Page 1
background image

Instrument Panel Control Module: Customer Interest
Instruments - Erratic Illumination/Control Functions

RANDOM RESET IN UPPER CONTROL PANEL CONTROL UNIT

Topic Number

LI54.21-P-047601

Version

1

Design Group

54.21 Control modules/modules

Date

08-18-2009

Validity

Module refinement vehicles, code 800, technical change status Pro 1
Affected VINs:
221 A 277 590 to 221 A 278936
216 A 023 123 to 216 A 023241

COMPLAINT:

switch and controls illumination, passenger side Airbag OFF lamp, switch illumination of upper control panel (UCP) control unit, instrument panel and
light switch flicker briefly (2.5 sec.), sometimes with brief (2.5 sec) display in instrument cluster "Parktronic Currently Unavailable", although the bar
display is functioning correctly.

CAUSE:

Resets are sporadically triggered in the UCP, causing the UCP to reboot the software.

REMEDY:

Flash UCP software. Old software 08/41.00, A 221 902 52 00, NEW software 08/48.00, A 221 902 95 00

Symptoms

Parts