CL 55 AMG (215.374) V8-5.5L SC (113.991) (2004)
allow it to dry.
4.
From the kit, install the re-circulating air valve with wiring adapter and dampening.
Caution!
The re-circulating air valve must be installed parallel/across from the Supercharger to ensure a leak proof connection. Follow steps 5 through 8
below.
5.
Start screws only of the re-circulating air valve first, and then mount the supercharger rigidly.
6.
Tighten front screws of the now aligned re-circulating air valve first.
7.
Remove supercharger again.
8.
Tighten rear screws of the re-circulating air valve at inter-cooler assembly.
Condition 2 in M113K: P202E stored in ME Control Unit of M113K engine.
Remedy 2: Install re-circulating air valve wiring harness adapter part number A113 150 08 33.
Parts Information
In Case of Warranty, use the table.