mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF30.20-P-2020V Throttle Valve Actuator, Component Description|Page 6427 > < GF30.20-P-2020V Throttle Valve Actuator, Component Description
Page 2
background image

Function

The actuator motor (M16/6m1) in the throttle valve actuator (M16/6) adjusts the opening angle of the throttle valve (1) continuously from approx. 0 to
90° according to presets from the ME-SFI [ME] control unit.

The typical power consumption of the pulse width modulation signal is approx. 1 A, however it is possible up to approx. 9 A. For output stage protection
the power is limited to 6 A after approx. 30 seconds. The actual value potentiometers (M16/6r3, M16/6r4) advise the current position of the throttle
valve to the ME-SFI [ME] control unit. The signals of both actual value potentiometer are opposed.

A. Ignition "Off"

In a deenergized state, the throttle valve position is determined by the spring capsule (3) (8 up to 10° opening angle).

B. Ignition "On"

When the ignition is switched on, the actuator motor in the throttle valve actuator is operated by the ME-SFI [ME] control unit.
The throttle valve adopts a position which depends on the coolant temperature.

C. Idle speed

Depending upon the coolant temperature and engine load, the actuator motor changes the rpm in the idle speed range by opening the throttle valve
further (increased mixture) or closing it further. (less mixture).
Here, the throttle valve can be closed further by the actuator motor against the force of the spring capsule.

D. Driving mode

In the driving mode (full / partial load), the actuator motor changes the throttle valve position depending on the different load states and / or
according to the input signals from the accelerator pedal sensor dependent on the performance maps.

E. Emergency running

If the actuator is deenergized, the throttle valve is set by the spring capsule to approx. 8 to 10° opening angle.
In the idle speed range, this results in an engine speed of approx. 1200 to 1400/min.

For first time connection of the throttle valve actuator to circuit 30 or 87, the ME-SFI [ME] control unit carries out automatically within approx. 60
seconds the following actions:

-

Determines the emergency running position

-

Determines lower mechanical stop

-

Matches the actual value amplifier (signal 1 and 2) in the MESFI [ME] control unit.

-

Checks the return spring (always takes place when ignition ON) Prerequisite: gear P or N, vehicle stationary, engine OFF, ignition ON, coolant
temperature 5 °C to 100 °C and accelerator pedal not operated.
The procedure must be activated with STAR DIAGNOSIS, if the throttle valve actuator or the ME-SFI [ME] control unit was replaced, otherwise
engine surges can occur.

GF30.20-P-2020V Throttle Valve Actuator, Component Description|Page 6427 > < GF30.20-P-2020V Throttle Valve Actuator, Component Description