mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF82.95-P-0001-01P TELE AID Position Of the Components|Page 14313 > < GF82.95-P-0001-01P TELE AID Position Of the Components|Page 14311
Page 9
background image

Then a voice connection (via telephone) is completed from the vehicle to the rescue service. The necessary help measures are introduced as a result of
this.

When initially started the system performs an authorization. An Emergency-Call emergency call cannot be made without authorization. The
Emergency-Call emergency call system does not function in the absence of authorization.

The system is comprised of:

^

D2B-capable vehicle equipment

^

mobile phone network (AMPS)

^

handset

^

emergency call center

^

telephone antenna (A2/22)

^

emergency call system left backup antenna (A2/54)

^

A2/55 emergency call system right backup antenna

AMPS network

The emergency call is directed to the emergency call center via the AMPS mobile network.

The vehicle equipment consists of the following components:

^

Localizing system integrated in the E-call control unit (A35/8) (GPS [global positioning system] receiver)

^

Tilting cone sensor (B66) integrated in the E-call control unit (A35/8) B66)

^

Car phone (AMPS module in control unit)

^

Existing vehicle sensors (crash sensor, wheel rpm sensors)

^

SOS pushbutton switch (S93/3)

GF82.95-P-2000Q TELE AID Switch-On/Switch-Off Characteristics, Function

GF82.95-P-2000Q TELE AID Switch-on/switch-off Characteristics, Function

- with CODE (855) TELE AID
- except CODE (498) Japan version
- except CODE (491) USA version

TELE AID emergency call switch-on characteristics

The TELE AID emergency call system is switched on with:

^

Circuit 15R ON

The switch-on procedure is indicated by the indicator lamp flashing (4 s) in the SOS pushbutton switch (S93/3). Moreover, the D2B telephone and TELE
AID transmitter/receiver (A35/17) waits for a ready confirmation from the restraint systems control unit (N2/7) after it was switched on. The system is
operational as soon as the ready confirmation is received. If the system is not authorized, an error message appears in the multifunction display (A1p13)
of the instrument cluster (A1) and the indicator lamp in the SOS pushbutton switch (S93/3) lights up.

TELE AID switch-on characteristics telediagnosis

The TELE AID telediagnosis is operational with:

^

Circuit 15C

^

telephone on

^

system authorized

^

telediagnosis pushbutton switch pressed

If the system is not authorized, an error message appears in the multifunction display (A1p13) of the instrument cluster (A1).

TELE AID telediagnosis switch-off characteristics

When the telephone is switched off, TELE AID telediagnosis is also deactivated.

TELE AID emergency call switch-off characteristics

GF82.95-P-0001-01P TELE AID Position Of the Components|Page 14313 > < GF82.95-P-0001-01P TELE AID Position Of the Components|Page 14311