Battery voltage below 9.5 V (undervoltage)

The COMAND operating, display and control unit (A40/3) is automatically put into a defined standby condition, in which only the battery voltage
continues to be monitored.

In addition to this the current operating status is stored. The COMAND operating, display and control unit (A40/3) cannot be operated or accessed using
STAR DIAGNOSIS when it is in this condition. Communication with external components does not take place. The following exceptions to the
switch-off characteristics (run-on mode) apply if the destination is not reached:

^

Up to t = 30 min navigation remains active (e.g., refueling stop). The navigation continues once the vehicle is restarted.

^

After t = 30 min up to a max. of 2 h the COMAND operating, display and control unit (A40/3) remains in "sleep mode". The route is calculated
again after the vehicle is restarted and the navigation continued.

^

After t = 2 hours have elapsed, a request is displayed when the vehicle is restarted asking if the route is to be calculated again
"YES" = Route is calculated again.
"NO" = Navigation will cease.

GF82.85-P-0003-07TXU Cockpit Management and Data System (COMAND) Switch On/Off
Characteristics

GF82.85-P-0003-07TXU Cockpit Management And Data System (COMAND) Switch On/Off Characteristics

Activation of entire system

When setting the transmitter key (A8/1) in the EIS control unit (N73) to position 0 (circuit 15C) all the bus systems are activated, in order to ensure a
faster switch-on procedure. At position 1 (circuit 15R ON) of the transmitter key (A8/1), the display on the COMAND operating, display and control
unit (A40/3) is switched on. This applies as long as before the last time the transmitter key (A8/1) was removed it was switched on.
The system which was active before it was last switched off (e.g. radio) is switched on and the corresponding basic menu is displayed. If the COMAND
operating, display and control unit (A40/3) was switched off for more than 30 minutes, then a message appears with general information about how to
use the system.

Conduct when pushing "ON" button

The COMAND operating, display and control unit (A40/3) can also be switched on when the transmitter key (A8/1) is removed by pressing the "ON"
button. All functions are then available for 30 minutes.

Navigation activation (with code (530) COMAND APS USA (with navigation))

The navigation system is activated automatically via the class B (interior) controller area network bus (CAN-B) when the driver door is opened. If the
digital versatile disk (DVD) is inserted, this process may be accompanied by faintly audible noises from the DVD drive integrated in the navigation
processor (N41/1). The display of the COMAND operating, display and control unit (A40/3) remains switched off.
If, as a result of this, no status change occurs at the EIS control unit (N73) e.g. "circuit 15C" or "circuit 15R ON", the navigation system remains
activated for t = 30 min. When 30 minutes has elapsed, the COMAND operating, display and control unit (A40/3) switches itself off automatically.
If switching off has occurred after 30 minutes, the system can be switched on again by pressing the "ON" button, thus the 30-minute run-on time starts
again.

Following the final navigation step (destination reached), the position map is switched on again. After 1 minute of run-on time has elapsed, the unit is
switched off completely.

Switch off characteristics

The COMAND operating, display and control unit (A40/3) is switched off when the transmitter key (A8/1) is removed ("circuit 15C OFF"). Then the 
navigation system run-on time of t = 30 min. starts (standby mode). During this run-on time all the important positioning parameters remain stored. The
audio system run-on time can be configured and is set ex-factory during installation of the COMAND operating, display and control unit (A40/3).
Moreover the COMAND operating, display and control unit (A40/3) is always in "standby" when CAN-B is active.

Switch off characteristics at undervoltage

The COMAND operating, display and control unit (A40/3) constantly monitors battery voltage. Depending on the voltage value the system will act as
follows:
If the battery voltage drops below 11.5 volts (battery warning range), a message appears on the display which requests the engine to be started. If the
engine is not started up, yet another warning is issued after 3 minutes have elapsed indicating that only 10 s remain to switch the engine on before the
system is run down. In this case switching on the engine prevents the system from being automatically shut down. If the system has shut off and the
on-board power supply increases again to more than 11.5 V, the COMAND operating, display and control unit (A40/3) does not switch itself on again
automatically.

If a system has been shut down it can still be switched back on again manually. The warning procedure then ensues for as long as the fault is not

GF82.85-P-0003-06TX Cockpit Management and Data System (COMAND), Volume and Tone Settings|Page 13430 > < GF82.85-P-0003-06TX Cockpit Management and Data System (COMAND), Volume and Tone Settings|Page 13428