mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Brakes - Fails STAR(R) Diagnosis Test/Air In System Mssg|Page 12673 > < Procedures|Page 12664
Page 1
background image

Brake Bleeding: All Technical Service Bulletins
Brakes - Fails STAR(R) Diagnosis Test/Air In System Mssg

Date: December 19, 2008

Order No.: P-B-42.46/102

Supersedes:

Group: 42

SUBJECT:

Model 211.022/026/056/065/070/076/082/087/256/265/276/282/283/287 MY 2003 - 2006

Model 219.375/376, MY 2006

All Model 230

Vehicle Fails STAR Diagnosis Test "Inspect Brake System For Air"

If you encounter instances in the above model vehicles of the Sensotronic Brake System (SBC) failing the STAR Diagnosis test  Inspect Brake System
for Air , perform the following.

1. When the vehicle initially fails the  Inspect Brake System for Air  test, follow the guided test procedures listed within STAR Diagnosis. If the issue

is still present after following the guided tests, proceed to step 2.

NOTE:  

Vehicles fail the STAR Diagnosis test "Inspect Brake System for Air" during the test of wheel brake circuit HZ1 (primary brake circuit) or
wheel brake circuit HZ2 (secondary brake circuit). STAR Diagnosis specifies air in the brake system as a potential cause. Only in this case
may a manual test of the maximum achievable pressure at the front axle be performed in hydraulic back-up mode.

2. Using STAR Diagnosis follow the menu path: Control Units -> Chassis -> SBC-Sensotronic Brake System -> Actual Values -> Pressures

NOTE:  

The SBC unit will now be in hydraulic back-up mode.

3. Actuate the brake pedal with maximum pedal force. The vehicle will pass the manual test if the left front pressure sensor (A7/3b3) and right front

pressure sensor (A7/3b4) each obtain a pressure of at least 90 bar.

4. If a value of 90 bar is not attained in the above test, then the front axle circuit must be bled with a reduced filling pressure (0.5 - 1.0 bar), as

instructed below in steps a - i.

a. Connect SBC hydraulic bleeding unit to vehicle and set pressure to 0.5   1.0 bar.

b. Using STAR Diagnosis follow the menu path: Control Units -> Chassis -> SBC Sensotronic Brake System -> Actual Values -> Pressures

c. Open bleed screw on the left front axle.

d. Bleed front axle circuit by slowly operating the brake pedal 3 times.

e. Close bleed screw on the left front axle.

f.

Open bleed screw on the right front axle.

g. Bleed front axle circuit by slowly operating the brake pedal 3 times.

h. Close bleed screw on the right front axle.

i.

Repeat the STAR Diagnosis test "Inspect Brake System for Air"

5. If the STAR Diagnosis test "Inspect Brake System for Air" fails at any other point other than those specified above, then there is still air in the

system. Bleeding the SBC system must be repeated with STAR Diagnosis routine "Bleed Brake System. The test "Inspect Brake System for Air"
must then be repeated.

6. If one or both of the front axle brake calipers were replaced, then the pistons of the brake calipers must be moved before starting the bleeding

Brakes - Fails STAR(R) Diagnosis Test/Air In System Mssg|Page 12673 > < Procedures|Page 12664