mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001T Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17644 > < AR83.10-P-2001T Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17642
Page 9
background image

6

Disconnect evaporator housing

NOTE:  Place to the side with electrical leads connected.

7

Unscrew bolts (4)

8

Detach right center vent air flap actuator motor(M2/13)

9

Install in the reverse order

10

Synchronize the stepper motors.

AR83.10-P-2019T Remove/Install Actuator For Center Outlet Flap

AR83.10-P-2019T Remove/Install Actuator For Center Outlet Flap

- without CODE (581b) Convenience automatic air conditioning

1

Remove evaporator housing

2

Remove bolts (1)

3

Remove center outlet flap actuator motor (2/22)

4

Disconnect electric connector (2)

5

Install in the reverse order

6

Synchronize the stepper motors.

AH83.10-P-0001-01T Information on Installing Actuator Motors

AH83.10-P-0001-01T Information On Installing Actuator Motors

Before assembling the actuator motors, check the condition of the adjustment mechanism. If damaged, remove the corresponding part from the
kinematics parts kit.

Parts needed for the basic automatic air conditioning:

AR83.10-P-2001T Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17644 > < AR83.10-P-2001T Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 17642