mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Campaign - Central Gateway Module Reflash|Page 21331 > < Campaign - Central Gateway Module Reflash
Page 2
background image

1.

Connect SDS to vehicle through the 16 pin diagnostic connector (X11/4).

2.

Software test CGW:

^

Navigate through the following screen menus in DAS to perform software test: Control units/Body/Central gateway/Control unit version.

^

An update must be performed for software with "MB object number for software" (bottom arrow, Figure 1): A211 445 20 00 A211 445 24 00
or A211 445 25 00, Software status" (top arrow) 03380 is displayed (refer to Subject B [Flash procedure] to perform update).

Note:

An update is not required for other MB object numbers or a different software release.  

B.

Flash procedure

Note:

Preflash requirements:
^

Battery voltage >11 volts

^

Connect battery charger

1.

Data back-up

Menu item "Information and Communication":

^

Navigate through the following screen menus in DAS: Control units/Information and Communication/ASSYST:

Print out: Actual values/Active service system since the last oil change.

^

Navigate through the following screen menus in DAS: Control units/Information and Communication/ASSYST PLUS:

Print out:

a) Actual values/CAN reception data

b) Actual values/Internal ASSYST PLUS data.

c) General servicing/Service memory