14.
Open the (gray) secondary lock in the SBC connector housing (A, Figure 9) by sliding the lock in the direction indicated by the arrows (Figure 9)
using a small screwdriver.
15.
Remove ground wires (arrows, Figure 10) from SBC harness connector (A):
^
Unpin SBC ground wire connectors (position 37 and 44, Figure 10) using cable release tool and remove from SBC connector housing (A)
(Special Tools: W 000 589 13 99 30 and W 220 589 01 99 50).
^
Discard old ground wire harness, it is no longer needed.
16.
Insert the new ground wiring harness (arrows Figure 10) into the SBC connector housing (A):
^
Insert longer ground wire into position 44.
^
Insert shorter ground wire into position 37.
Note:
Ensure ground wire connectors are properly locked into place.