mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF07.10-P-1017MI Intake Manifold Switchover, Function|Page 3524 > < Variable Induction Control Actuator|Locations|Page 3519
Page 1
background image

Variable Induction Control Valve: Description and Operation
GF07.10-P-1017MI Intake Manifold Switchover, Function

GF07.10-P-1017MI Intake Manifold Switchover, Function

Function requirements for intake manifold switchover, general points

^

Circuit 87M ON (engine control ON)

^

Engine running

Intake manifold switchover, general points

The intake manifold switchover is used to switch between the long and short intake tracts. This optimizes the engine torque.

The ME-SFI [ME] control unit (N3/10) actuates the intake manifold switchover according to the signals from the following sensors:

-

Hot film MAF sensor (B2/5), engine load

-

Crankshaft Hall sensor (B70), engine speed

Function sequence for intake manifold switchover

For the intake manifold switchover, the ME-SFI [ME] control unit uses a ground signal to actuate the intake manifold switchover valve (Y22/6),
according to engine load and engine speed.

Engine 272

The variable length intake manifold switchover flaps for a cylinder bank are linked to each other by a spindle and are each actuated by a vacuum unit.
The vacuum units are connected by hose lines to the intake manifold switchover valve.

When the intake manifold switchover valve is not actuated, the vacuum units are ventilated and the switchover flaps are opened by spring force.
Air intake takes place over the short intake tracts.

When the intake manifold switchover valve is actuated, the vacuum units are charged with vacuum from the vacuum reservoir. This causes the
switchover flaps to close, and air is admitted through the long intake tract.

Engine 273

The switchover flaps for each cylinder bank are linked to each other by means of a shaft. The two shafts are joined by a linkage and are actuated together
by a vacuum unit.

The vacuum unit is connected to the intake manifold switchover valve by a hose line.

When the intake manifold switchover valve is not actuated, the vacuum unit is ventilated and the switchover flaps are opened by spring force.
Air intake takes place over the short intake tracts.

When the switchover valve is actuated, the vacuum unit is charged with vacuum from the vacuum reservoir. This causes the switchover flaps to close,
and air is admitted through the long intake tract.

Short intake tracts (section in cylinder level)

GF07.10-P-1017MI Intake Manifold Switchover, Function|Page 3524 > < Variable Induction Control Actuator|Locations|Page 3519