mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF54.30-P-0002-05T Instrument Cluster (IC), Operating Information|Page 20158 > < GF54.30-P-0002-05T Instrument Cluster (IC), Operating Information|Page 20156
Page 7
background image

until the desired menu item "Vehicle" is active on the multifunction display (A1p13),

Press the scroll forward/back button (S110s1) until the display of the setting to be changed appears on the multifunction display (A1p13). Press the + and
-, specific function setting and volume control button (S111s1) in either the "+ -" or "-" direction until the value you require is displayed on the
multifunction display.A1p13
The activated value becomes effective immediately.

Overview and sequence of settings in the menu item "Comfort"

Change setting in menu item "Comfort"

Press the system selection button (S110s3) until the "Settings" function appears on the multifunction display (A1p13), go to the corresponding menu item
using the scroll forward/back button (S110s1). Press pushbutton + and -, setting specific functions and volume control (S111s1) in the (+) or (-) direction
until the desired menu item "Comfort" is active on the multifunction display (A1p13), Press the scroll forward/back button (S110s1) until the display of
the setting to be changed appears on the multifunction display (A1p13). Press the + and -, specific function setting and volume control button (S111s1)
in either the "+ -" or "-" direction until the value you require is displayed on the multifunction display.A1p13
The activated value becomes effective immediately.

Settings are selectable regardless of the vehicle speed.

Example: Switching over from degrees Centigrade to degrees Fahrenheit (up to 31.5.05)

Press the system selection button (S110s3) until the "settings" function appears on the multifunction display (A1p13), go to the corresponding menu item
using the scroll forward/back button (S110s1). Press the button + and -, setting of specific functions and volume control (S111s1) towards (+) or (-) until
the desired menu item "Instrument cluster" is active on the multifunction display (A1p13). Press the scroll forward/back button (S110s1) until the display
"TEMPERATURE DISPLAY" appears on the multifunction display (A1p13). Press the button + and -, setting of specific functions and volume control
(S111s1) towards (-) on the right-hand side of the steering wheel so that Fahrenheit is now active on the multifunction display (A1p13). The setting
becomes effective immediately.

As of 1.6.05 it is no longer possible for the user to change over from degrees Centigrade to degrees Fahrenheit.

Recalling the factory settings

All the possible settings are erased and the manufacturer default setting reproduced by a "Reset".

Carry out reset

Press the system selection button (S110s3) until the "SETTINGS" function appears on the multifunction display (A1p13). Operate the instrument
lighting dimmer and reset button (A1r1) for at least 3 s. "RESET SETTINGS, CONFIRMATION WITH RESET BUTTON" appears on the
multifunction display (A1p13). Operate the instrument lighting dimmer and reset button (A1r1) once more within 5 s, all the settings are now reset to the
factory setting "RESET TO MANUFACTURER SETTING" appears on the multifunction display (A1p13). If the instrument illumination rheostat and

GF54.30-P-0002-05T Instrument Cluster (IC), Operating Information|Page 20158 > < GF54.30-P-0002-05T Instrument Cluster (IC), Operating Information|Page 20156