G 55 AMG (463.246) V8-5.5L (113.982) (2005)
Component Identification
Application of sealant to end cover
The lines drawn G, E and the arrow D mark the application of sealant.
Clean sealing surfaces, apply sealant only to the specified surfaces with a bead of 2.0 mm ± 0.5 mm.
The sealant must be applied within 10 minutes!
The silicone bead must not be spread. Only the approved silicone sealant may be used may be used.