background image

Climate control LIN

The following components are actuated via climate control LIN:

-

Blower regulator (A32n1)

-

Fresh air/air recirculation flaps actuator motor (M2/5)

-

Left blend air flap actuator motor (M2/6)

-

Right blend air flap actuator motor (M2/7)

-

Rear shutoff flap actuator motor (M2/12)

-

Footwell flap actuator motors left and right (M2/15)

-

Defroster vent flap actuator motors left and right (M2/16)

-

Rear air distribution flap actuator motor (M2/21)

-

Center air outlet flap actuator motor (M2/22)

-

PTC heater booster (R22/3) (with diesel engine)

Interior CAN

The following components are actuated with the interior CAN:
By the rear SAM control unit:

-

Rear window defroster

By the central gateway control unit:

-

AAC with integrated control additional fan motor (M4/7)

From the left front door control unit:

-

Left front power window motor (M10/3)

From the right front door control unit:

-

Right front power window motor (M10/4)

By the front SAM control unit:

-

Left rear power window motor (M10/5)

-

Right rear power window motor (M10/6)

By the rear SAM control unit on model 164.8 and model 251.0/1 with code (848) Electric side vent window

-

Left vent window motor

-

Right vent window motor

By the overhead control panel control unit
with code (414) Power glass tilting/sliding sunroof

-

SR motor (M12m1),

For code (413) Panoramic glass roof with top sliding roof:

-

Roller sun blind drive unit (M12/5)

-

Panoramic sliding sunroof drive unit 1 (M12/6)

-

Panoramic sliding sunroof drive unit 2 (M12/7)

On model 164.195:
via the central gateway control unit and via engine compartment CAN (CAN C):

-

Electric refrigerant compressor control unit

GF83.40-P-3000GM Component Description For Automatic Air Conditioning Control and Operating Unit|Page 11260 > < GF83.40-P-3000GM Component Description For Automatic Air Conditioning Control and Operating Unit|Page 11258