Air Door Actuator / Motor: Description and Operation
GF83.10-P-2201GZ Actuator Motors, Component Description

GF83.10-P-2201GZ Actuator Motors, Component Description

- with CODE (580) Automatic air conditioning

Component Identification

Location

The actuator motors are located in the A/C housing.

Task
General determinations on actuator motor and flap controls

Continuous positioning of the flaps.
The following release function is realized for each flap in the automatic air conditioning to prevent the actuator motors from operating continuously in
the controlled range.
Release function: This is a position which, once set, must change so much up to the next change, e.g. blower stage temperature setting, that the release
value above or below is exceeded or dropped below.
Final values are approached directly (0 %, 100 %).

Anti-fogging function

The anti-fogging function prevents the windshield and side windows from fogging up after starting the engine by blowing the moist air, immediately after
starting, into the vehicle footwell instead of against the windows.

Center outlet flap actuator motor

The center outlet flap actuator motor actuates the air flaps for controlling the air flow to the center nozzle.
The center outlet flap actuator motor is actuated by the AAC control and operating unit (N22) depending on the air outlet temperature desired at the
center nozzle.

Actuation for "Defrost"

Center outlet flap 0 % (closed)

Actuation for "Rest"

according to control

Actuation for "0"

remain in previous condition

Actuation for ignition OFF

remain in previous condition

Automatic air flap control

The air flaps are opened according to a defined characteristic up to 100 % by the center outlet flap actuator motor, depending on the following values:

^

Blending air flap setting

^

Coolant temperature

^

Evaporator temperature

^

Footwell flap position

Air flap control via the center nozzle