Shift Solenoid: Description and Operation
Models With Touch Shift

Upshift/Downshift Solenoid Valve

Position/Task/Design/Function

Component Illustration

Position

In the shell of the electric control unit and pressed against the shift plate with a spring.

Task

The solenoid valves (Y3/6y3, Y3/6y4, Y3/6y5) initiate the upshift and downshift procedures in the shift plate.

Design

The solenoid valves (Y3/6y3, Y3/6y4, Y3/6y5) are sealed off from the valve housing of the shift plate (2a) by two O-rings (34, 35). The contact
springs (32) at the solenoid valve engage in a slot in the conductor tracks (33). The force of the contact spring (32) ensures safe contacts.

Function

If a solenoid valve is actuated by the ETC control module (N15/3), it opens and guides the control pressure (p-SV) to the assigned command valve
(31). The solenoid valve remains actuated and therefore open until the shifting process is complete. The shift pressure (p-SV) to the command valve is
reduced to zero as soon as the power supply to the solenoid valve is interrupted.