Function
The AAC pushbutton control module (N22) passes a control voltage of 0 - 6 V to the blower regulator (A32n1) via the AC bus. Depending on the
control voltage which is present, this then regulates the blower motor (A32m1) operating voltage of 0 - 12 V. This facilitates blower speed control of 0 -
100 %.
The blower motor actuation (operating voltage) is influenced by the following factors:
-
Blower power setting manual or AUTO
-
Operating functions:
Air distribution
AC OFF mode
Residual engine heat mode (actuation limited to 5 V)
-
Mode status (heating, cooling)
-
Coolant temperature
-
Vehicle speed
-
Fresh air/recirculation flap setting
-
Flap positions
-
Terminal 15 (blower ON), starter running (blower OFF)