GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 15837 > < GF54.21-P-6040GZ Upper Control Panel Control Module Component Description
Page 2
background image

Level control switch

Function requirements:

-

Term. 15 "ON"

Switch actuations enable the driver to choose between a highway level and a raised level. The vehicle is in the highway level state (no function
indicator). If the vehicle is lifted to the raised level, the LED in the switch flashes on and off. When the level is reached the LED remains constantly on.
The last stage selected with function indicator is active once the engine is started again.

Hazard warning system switch

Pressing the hazard warning system switch wakes-up the upper control panel control unit from its "Sleep mode" and the hazard warning system function
is activated. The message is sent cyclically (every 100 ms) until the function is deactivated by pressing the hazard warning system switch again. The
flashing function illumination of the hazard warning system switch is triggered by the CAN message of the rear SAM control unit (N10/8). There is no
faster flashing of a defective indicator lamp for the hazard warning flasher system. As soon as the hazard warning flasher function is activated the switch
and controls illumination for the hazard warning system switch is switched off. The function illumination of the hazard warning system is not dimmed.

The selected function is confirmed when the indicator lamps (LEDs) light up. The pulse to light up is sent by each respective control unit.

PTS OFF switch

The Parktronic system is activated or deactivated via the PTS OFF switch. If the switch is actuated, the upper control panel control unit sends a signal to
the PTS control unit (N62) via CAN-B. The PTS control unit then sends a message requesting actuation of the status LED in the PTS OFF switch back
to the upper control panel control unit.

Left front HS [SIH] switch and right front HS [SIH] switch

The heated seats have 3 stages. One-time actuation of the SIH switch activates stage 3 of the heated seats (all 3 red LEDs light up). Further actuations
switch to stage 2 (the two lower LEDs go on), to stage 1 (the lowest LED goes on), or the heated seats are switched off (no function indicator). The
function requirements for this switch is circuit 15R "ON". Each press of the left front HS [SIH] switch and right front HS [SIH] switch is sent by the
upper control panel control unit over the CAN-B.

Left front seat ventilation switch and right front seat ventilation switch (only model 164.8)

When the left front and right front seat ventilation switch is actuated, the upper control panel control unit sends a signal to the HS [SIH], seat ventilation
and steering wheel heater control unit (N25/7) via CAN-B.

The switch is used to switch the seat ventilation in the respective seat on and off, and also to control the ventilation output. The level of ventilation
output is displayed by indicator lamps in the respective switch.

Downhill Speed Regulation switch

The driver can switch the DSR on and off using the Downhill Speed Regulation switch. A red LED integrated into the switch indicates whether the
function is active or not. Downhill Speed Regulation is an aid for driving down hills with an adjustable speed that can be set between 4 and 18 km/h.

Offroad program switch

The offroad program switch is used to adjust the dynamic characteristics of the vehicle in order to optimize traction and forward propulsion in offroad
operation
(e.g. by changing the shifting behavior of the automatic transmission).

STH switch

The function of the STH switch depends on the current terminal status. Whenever the stationary heater is activated, the AAC [KLA] control and
operating unit (N22) receives a query as to whether heating or ventilation is required. The currently active function is displayed by an indicator lamp in
the STH switch as follows:

-

Indicator lamp red: Heating mode

-

Indicator lamp blue: Ventilation mode

-

Indicator lamp yellow: Activation of stationary heater via timer

Function with terminal 15R OFF

If the switch is actuated, the system is switched on or off immediately. When switched on, the upper control panel control unit sends a signal to the heater
booster control unit (N33/2). The latter then sends the command to switch on the stationary heater to the AAC [KLA] control and operating unit.

GF54.21-P-6040GZ Upper Control Panel Control Module Component Description|Page 15837 > < GF54.21-P-6040GZ Upper Control Panel Control Module Component Description