Component Identification

1

Position adapter for rear axle differential (8b) on rear axle differential and fix in position with the right-hand knurled screw (13a) and left-hand
knurled screw (13b).

2

Align adapter for rear axle differential (8b) using the spirit level.

Check seat of adapter for rear axle differential (8b).

If the location of the sensor (086a) deviates excessively from the horizontal, an error message appears on the display of the measuring instrument,
no value can be read off or stored.

3

Place sensor (086a) on the support plate.

The cable (10) must point forwards (arrow), otherwise an incorrect measurement occurs.

Ensure that the sensor (086a) is seated correctly in the bores of the support plate, otherwise an incorrect measurement occurs.

4.1

Read off the absolute angle on the flange of the rear axle differential (6) on the display of the measuring instrument and enter in the data sheet.

If the electronic inclinometer is used or if a measurement is made with the electronic propeller shaft inclinometer in inclination measuring
mode.

The X-value must be read off on the display Otherwise incorrect results occur.

The measured value must not be stored.

The absolute angle at the flange of the rear axle differential (6) may only be read off if the sensor (086a) on standby and the displayed value is
constant.

Procedures|Page 9334 > < Procedures|Page 9332