Component Identification

1

Mount the sensor (086a) directly on the front propeller shaft (2) and align with the horizontal.

The cable must point in the direction of travel (arrow), otherwise an incorrect measurement will occur.

If the position of the sensor (086a) deviates too much from the horizontal, a fault message appears on the measuring instrument display, no value
can be read off or stored.

2.1

Read off absolute angle of the front propeller shaft (2) on the measuring instrument display and enter in the data sheet.

If the electronic inclinometer is used or if measurements are made in inclination measuring mode with the electronic articulation/propeller shaft
inclinometer

The X-value must be read off on the display. Otherwise incorrect measurement results occur.

The measured value must not be stored.

The absolute angle of the front propeller shaft (2) may only be read off if the sensor (086a) is on standby and the displayed value is constant.

2.2

Store the absolute angle of the front propeller shaft (2) in the measuring instrument.

If the electronic propeller shaft inclinometer with memory extension or the electronic articulation/propeller shaft inclinometer with memory
extension is used in articulation angle measuring mode.

Save the measured value by pressing the SAVE button. After this the measurement readiness for the third angle is displayed.

The absolute angle of the front propeller shaft (2) may only be stored if the sensor (086a) is on standby and the displayed value is constant.

AR41.10-P-0085-09RT Measure the Absolute Angle at the Flange of the Transfer Case

AR41.10-P-0085-09RT Measure the absolute angle at the flange of the transfer case

Data Sheet for Measuring Inclination Angle, Form