mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Oxygen Sensor I and II|Page 3191 > < Oxygen Sensor I and II|Page 3189
Page 2
background image

  Oxygen Sensor Voltage

SIGNAL

A rich mixture will produce a high voltage (up to 1.0V) and a lean mixture will produce a lower voltage. Oxygen sensor I sends the signal to the
HFM-SFI control module. Oxygen sensor II sends the signal to the diagnostic module. 

Oxygen Sensor Heater Signal

PURPOSE

To keep the oxygen sensors (G3/1 and G3/2) at a consistant operating temperature (approx. 600 °C / 1112 °F), the HFM-SFI control module
controls the oxygen sensor heating element. (Either directly or through the relay module (K35) depending on model. Refer to wiring diagram.)

OPERATION

When the engine is started, the oxygen sensor heating element is in operation. If the engine exceeds 5500 RPM, the heating element is turned off.
Operation restarts when the engine speed drops below 5000 RPM. 

GF07.04-P-4103-01F O2 Sensors Function

GF07.04-P-4103-01F O2 Sensors Function

The sensor ceramic is conductive for oxygen ions from approx. 300 degrees C. If the oxygen share varies greatly on both sides of the ceramic probe
body, a voltage (Nernst concentration cell) is generated on the friction planes by means of the particular properties of the ceramic probe body on the
friction plane. This is a measure for the residual oxygen content in the exhaust.

Oxygen Sensor I and II|Page 3191 > < Oxygen Sensor I and II|Page 3189