Blower Motor: Service and Repair
AR83.50-P-9040M Remove/Install Rear Blower Motor

AR83.50-P-9040M Remove/Install Rear Blower Motor

- with CODE (582) Rear air conditioning

DANGER:

-

Explosion hazard when performing welding or brazing work on closed air conditioning. Poisoning hazard from inhaling overheated 
refrigerant vapors. Injury hazard from skin and eye contact with liquid refrigerant.

-

Do not perform any type of welding work on closed air conditioning system or in its vicinity. Smoking and open flame prohibited.

-

Wear protective goggles and protective gloves, work only in well-ventilated rooms. Perform repair work on air conditioning circuit only
with system emptied.

CAUTION:  Protect air conditioning circuit and components from moisture during repair work.

1

Empty air conditioning (recycle), evacuate, charge, check for leaks

CAUTION:  Add quantity of compressor oil removed to refrigerant circuit when charging air conditioning (new oil).