S 600 (220.176) V12-5.5L Turbo (275.960) (2005)
Revisions
14.10.98 Synchronization of actuator motors Step 7, newly included
1
Remove glove compartment
2
Remove cover from center console (3)
3
Disconnect actuator motor connector (4)
NOTE: Connection and disconnection aid.
4
Unscrew screws (2)
5
Pull off actuator for right defroster vent flap actuator motor (M16/14)
6
Reinstall in opposite order.
7
Perform synchronization of actuator motors.
AR83.30-P-2050M Remove/Install Actuator For Left Center Blend Air Flap
AR83.30-P-2050M Remove/Install Actuator For Left Center Blend Air Flap