mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Evaporator Drain Tube > < Procedures|Page 8305
Page 5
background image

DANGER:

-

Explosion hazard when performing welding or brazing work on closed air conditioning. Poisoning hazard from inhaling overheated 
refrigerant vapors. Injury hazard from skin and eye contact with liquid refrigerant.

-

Do not perform any type of welding work on closed air conditioning system or in its vicinity. Smoking and open flame prohibited.

-

Wear protective goggles and protective gloves, work only in well-ventilated rooms. Perform repair work on air conditioning circuit only
with system emptied.

CAUTION:  Protect air conditioning circuit and components from moisture during repair work.

1

Empty air conditioning (recycle), evacuate, charge, check for leaks

CAUTION:  Add quantity of compressor oil removed to refrigerant circuit when charging air conditioning (new oil).

2

Remove rear A/C housing (1)

3

Unclip 8 clips (2)

4

Remove housing upper section (3)

5

Remove evaporator (4)

6

Replace receiver/drier

7

Install in opposite order.

Evaporator Drain Tube > < Procedures|Page 8305