S 600 (220.176) V12-5.5L Turbo (275.960) (2005)
DANGER:
-
Explosion hazard when performing welding or brazing work on closed air conditioning. Poisoning hazard from inhaling overheated
refrigerant vapors. Injury hazard from skin and eye contact with liquid refrigerant.
-
Do not perform any type of welding work on closed air conditioning system or in its vicinity. Smoking and open flame prohibited.
-
Wear protective goggles and protective gloves, work only in well-ventilated rooms. Perform repair work on air conditioning circuit only
with system emptied.
CAUTION: Protect air conditioning circuit and components from moisture during repair work.
1
Empty air conditioning (recycle), evacuate, charge, check for leaks
CAUTION: Add quantity of compressor oil removed to refrigerant circuit when charging air conditioning (new oil).
2
Remove rear A/C housing (1)
3
Unclip 8 clips (2)
4
Remove housing upper section (3)
5
Remove evaporator (4)
6
Replace receiver/drier
7
Install in opposite order.