S 600 (220.176) V12-5.5L Turbo (275.960) (2005)
Voltage Regulator: Testing and Inspection
Check regulation voltage of generator
Connection Diagram
Testing
DANGER:
-
Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through
burns to skin and eyes from battery acid or when handling damaged lead-acid batteries.
-
No fire, sparks, naked flames or smoking. Wear acid-resistant gloves, clothing and glasses. Pour battery electrolyte only into suitable
and appropriately marked containers.
1
Measure acid density
-
See "Commercially Available Tools" below.
Acid density below minimum value, Charge battery.
-
See "Test and adjustment values for battery, voltage supply" given below.
2
Preconditions for generator test
3
Connect multimeter (003) according to connection schematic
-
See "Commercially Available Tools" below.