AH01.40-P-1000-03A Information on Application of Sealant to Crankcase Bottom Section
AH01.40-P-1000-03A Information on application of sealant to crankcase bottom section
Sealing agent flow
Sealing agent flow
The line drawn in (F) identifies the sealing compound application.
The sealant must be applied only to the specified surfaces with a bead of 2.0 mm ± 0.5 mm. The sealing compound must be applied within 10 min.
The bead should not be spread. Only the approved silicone sealant may be used.